MSL vs breaking load Allowed load vs the load that breaks it
Breaking load is the force at which a lashing or fitting is expected to fail. MSL is the much lower force it may take in service at sea, set as a share of the breaking load under the CSS Code. Securing plans use MSL, never breaking load.
Worked example
A chain lashing with a breaking load of 200 kN.
- CSS Code Annex 13: MSL for chain = 50% of breaking load
- MSL = 200 × 0.5 = 100 kN
- A plan that counts 200 kN per chain overstates it twice over
The terms
- MSL Maximum securing load
- Breaking load BL or MBL: minimum breaking load
- CS Calculated strength
- CSS Code Code of Safe Practice for Cargo Stowage and Securing
Sources
- CSS Code with Annex 13 (MSC/Circ.664 and 1026 text), Netherlands Regulatory Framework (official copy) (puc.overheid.nl). Opened 26 Oct 2026.
Checked 27 Oct 2026 · next check January 2027. Meanings can differ by trade and contract: check your own documents.